Contact Person: IVY ZHANG
Tel: +86 022 84995960
Mobile Phone: +86 13902042869
E-mail: info@ot-automation.com
SKype: IVY ZHANG-CHINA ONE-TONE
Whatsapp: +86 13902042869
Add: Room 103-27, No. 3 Xianggang Street, Jinnan Economic Development Zone, Tianjin, China
SIEMENS SINAMICS G110 AC DRIVE is a frequency inverter with basic functions for a variation of industrial variable-speed drive applications. The predominantly compact SIEMENS SINAMICS G110 inverter operates with voltage frequency control on single-phase supplies (200 V to 240 V). It is the ideal low-cost frequency inverter solution for the lesser power range of the SIEMENS SINAMICS family
The SINAMICS G110 AC DRIVE is a micro frequency inverter for regulating the speed of three phase AC motors. Several available models range from 1/6hp to 4hp (120W to 3kW), single-phase 200V to 240V input. The plainness of the SINAMICS G110 and its included basic functionality makes it an ideal choice for a wide variety of industrial variable speed drive applications. These inverters are microprocessor-controlled and compact in size. They mount and wire like a contactor. The SINAMICS G110 uses state-of-the-art Insulated Gate Bipolar Transistor (IGBT) and microprocessor technology that makes them very reliable and versatile.
Performance Features
• Latest IGBT technology
• Digital microprocessor control
• Programmable Linear V/Hz control or Quadratic V/Hz control
• Fast, repeatable digital input response time
• Programmable acceleration/deceleration, 0s to 650s
• Adjustable ramp smoothing
• Flying restart
• Automatic restart following power failure or fault
• Boost and Slip Compensation for good speed control
• Fast current limit (FCL) for trip free operation
• Injection braking for rapid stopping
• One skip frequency
• The optional Basic Operator Panel (BOP) provides programming, monitoring and drive-cloning capabilities
• An optional PC Connection Kit allows RS232 connection for monitoring and programming
Main Characteristics
• Stress-free installation
• Easy commissioning -- No programming required. Factory pre-programmed for 4-pole NEMA or IEC motors; digital input control for switching the inverter "on", "reversing," and "fault reset;" and analog set point speed control
• Rough design
• Constant, repeatable response time to control signals
• Complete range of parameters allowing configuration for a wide range of applications
• One isolated opt coupler output
Three digital inputs• One analog input, 0-10VDC for frequency setpoint (Alternate version available with RS485 port - US protocol
• Status information and alarm messages via LED lights
6SL3211-0AB12-5UB1 | SIEMENS AC DRIVE SINAMICS VFD G110 - CPM110 AC-DRIVE, EXCLUSIVE FILTER 1AC200-240V +10/-10% 47-63HZ RS485-INTERFACE (USS-PROTOCOL) CT: 0.25KW; VT: 0.25KW CT-OVERLOAD: 150% 60S 150 X 90 X 116 (HXWXD) INPUT |
6SL3211-0AB13-7BA1 | SIEMENS AC DRIVE SINAMICS VFD G110 - CPM110 AC-DRIVE,BUILT IN CL. B FILTER 1AC200-240V +10/-10% 47-63HZ ANALOG INPUT CT: 0.37KW; VT: 0.37KW CT-OVERLOAD: 150% 60S 150 X 90 X 116 (HXWXD) |
6SL3211-0AB13-7BB1 | SIEMENS AC DRIVE SINAMICS VFD G110 - CPM110 AC-DRIVE,BUILT IN CL. B FILTER 1AC200-240V +10/-10% 47-63HZ RS485-INTERFACE (USS-PROTOCOL) CT: 0.37KW; VT: 0.37KW CT-OVERLOAD: 150% 60S 150 X 90 X 116 (HXWXD) |
6SL3211-0AB13-7UA1 | SIEMENS AC DRIVE SINAMICS VFD G110 - CPM110 AC-DRIVE, EXCLUSIVE FILTER 1AC200-240V +10/-10% 47-63HZ ANALOG INPUT CT: 0.37KW; VT: 0.37KW CT-OVERLOAD: 150% 60S 150 X 90 X 116 (HXWXD) |
6SL3211-0AB13-7UB1 | SIEMENS AC DRIVE SINAMICS VFD G110 - CPM110 AC-DRIVE, EXCLUSIVE FILTER 1AC200-240V +10/-10% 47-63HZ RS485-INTERFACE (USS-PROTOCOL) CT: 0.37KW; VT: 0.37KW CT-OVERLOAD: 150% 60S 150 X 90 X 116 (HXWXD) INPUT |
6SL3211-0AB15-5BA1 | SIEMENS AC DRIVE SINAMICS VFD G110 - CPM110 AC-DRIVE,BUILT IN CL. B FILTER 1AC200-240V +10/-10% 47-63HZ ANALOG INPUT CT: 0.55KW; VT: 0.55KW CT-OVERLOAD: 150% 60S 150 X 90 X 131 (HXWXD) |
6SL3211-0AB15-5BB1 | SIEMENS AC DRIVE SINAMICS VFD G110 - CPM110 AC-DRIVE,BUILT IN CL. B FILTER 1AC200-240V +10/-10% 47-63HZ RS485-INTERFACE (USS-PROTOCOL) CT: 0.55KW; VT: 0.55KW CT-OVERLOAD: 150% 60S 150 X 90 X 131 (HXWXD) |
6SL3211-0AB15-5UA1 | SIEMENS AC DRIVE SINAMICS VFD G110 - CPM110 AC-DRIVE, EXCLUSIVE FILTER 1AC200-240V +10/-10% 47-63HZ ANALOG INPUT CT: 0.55KW; VT: 0.55KW CT-OVERLOAD: 150% 60S 150 X 90 X 131 (HXWXD) |
6SL3211-0AB15-5UB1 | SIEMENS AC DRIVE SINAMICS VFD G110 - CPM110 AC-DRIVE, EXCLUSIVE FILTER 1AC200-240V +10/-10% 47-63HZ RS485-INTERFACE (USS-PROTOCOL) CT: 0.55KW; VT: 0.55KW CT-OVERLOAD: 150% 60S 150 X 90 X 131 (HXWXD) INPUT |
6SL3211-0AB17-5BA1 | SIEMENS AC DRIVE SINAMICS VFD G110 - CPM110 AC-DRIVE,BUILT IN CL. B FILTER 1AC200-240V +10/-10% 47-63HZ ANALOG INPUT CT: 0.75KW; VT: 0.75KW CT-OVERLOAD: 150% 60S 150 X 90 X 131 (HXWXD) PROTECTION IP20 AMBIENT TEMP -10 TO +40 DEG C |
6SL3211-0AB17-5BB1 | SIEMENS AC DRIVE SINAMICS VFD G110 - CPM110 AC-DRIVE,BUILT IN CL. B FILTER 1AC200-240V +10/-10% 47-63HZ RS485-INTERFACE (USS-PROTOCOL) CT: 0.75KW; VT: 0.75KW CT-OVERLOAD: 150% 60S 150 X 90 X 131 (HXWXD) PROTECTION IP20 AMBIENT TEMP -10 TO +40 DEG C |
6SL3211-0AB17-5UA1 | SIEMENS AC DRIVE SINAMICS VFD G110 - CPM110 AC-DRIVE, EXCLUSIVE FILTER 1AC200-240V +10/-10% 47-63HZ ANALOG INPUT CT: 0.75KW; VT: 0.75KW CT-OVERLOAD: 150% 60S 150 X 90 X 131 (HXWXD) PROTECTION IP20 AMBIENT TEMP -10 TO +40 DEG C |
6SL3211-0AB17-5UB1 | SIEMENS AC DRIVE SINAMICS VFD G110 - CPM110 AC-DRIVE, EXCLUSIVE FILTER 1AC200-240V +10/-10% 47-63HZ RS485-INTERFACE (USS-PROTOCOL) CT: 0.75KW; VT: 0.75KW CT-OVERLOAD: 150% 60S 150 X 90 X 131 (HXWXD) PROTECTION IP20 AMBIENT TEMP -10 TO +40 DEG C INPUT |
6SL3211-0AB21-1AA1 | SIEMENS AC DRIVE SINAMICS VFD G110 - CPM110 AC-DRIVE,BUILT IN CL. A FILTER 1AC200-240V +10/-10% 47-63HZ ANALOG INPUT CT: 1.1KW; VT: 1.1KW CT-OVERLOAD: 150% 60S 160 X 140 X 142 (HXWXD) |
6SL3211-0AB21-1AB1 | SIEMENS AC DRIVE SINAMICS VFD G110 - CPM110 AC-DRIVE,BUILT IN CL. A FILTER 1AC200-240V +10/-10% 47-63HZ RS485-INTERFACE (USS-PROTOCOL) CT: 1.1KW; VT: 1.1KW CT-OVERLOAD: 150% 60S 160 X 140 X 142 (HXWXD) |
6SL3211-0AB21-1UA1 | SIEMENS AC DRIVE SINAMICS VFD G110 - CPM110 AC-DRIVE, EXCLUSIVE FILTER 1AC200-240V +10/-10% 47-63HZ ANALOG INPUT CT: 1.1KW; VT: 1.1KW CT-OVERLOAD: 150% 60S 160 X 140 X 142 (HXWXD) |
6SL3211-0AB21-1UB1 | SIEMENS AC DRIVE SINAMICS VFD G110 - CPM110 AC-DRIVE, EXCLUSIVE FILTER 1AC200-240V +10/-10% 47-63HZ RS485-INTERFACE (USS-PROTOCOL) CT: 1.1KW; VT: 1.1KW CT-OVERLOAD: 150% 60S 160 X 140 X 142 (HXWXD) INPUT |
6SL3211-0AB21-5AA1 | SIEMENS AC DRIVE SINAMICS VFD G110 - CPM110 AC-DRIVE,BUILT IN CL. A FILTER 1AC200-240V +10/-10% 47-63HZ ANALOG INPUT CT: 1.5KW; VT: 1.5KW CT-OVERLOAD: 150% 60S 160 X 140 X 142 (HXWXD) PROTECTION IP20 AMBIENT TEMP -10 TO +40 DEG C |
The SIEMENS SINAMICS G110 inverter is especially suited for applications with pumps and fans, as a drive in various sectors, e.g. food and beverages, textiles, packaging, as well as conveyor technology, with factory gate and garage door drives and as a universal drive for moving advertising media.